Case study · Aerospace
Military Helicopter Bearings
Extended Bearing Operation After Sudden Lubrication Loss
In comparative testing, a Dicronite® dry-lubricated M-50 steel roller bearing continued operating for 38 minutes after lubrication loss, while standard bearings failed within 3–6 minutes.
The treated bearing operated for the full test duration—more than six times the longest reported operating time of the untreated bearings.
- 38min Continued operating after lubrication loss The full test duration, with no reported failure.
- 3–6min Standard bearings failed Under the same lubrication-loss conditions.
- >6× Longer operation Than the longest reported time of the untreated bearings.
The challenge
Sudden lubricant loss in combat transmissions
Combat helicopter transmissions can experience sudden lubricant loss following damage from enemy fire. Extending transmission operation after lubrication loss can give the crew additional time to reach a suitable emergency landing site.
Testing evaluated whether Dicronite dry lubrication could extend bearing operation under these conditions.
What the testing evaluated
Operating timeBearing operation after sudden lubrication loss.
More time can help the crew reach a suitable emergency landing site.
The testing
Standard bearings versus treated bearings
Standard M-50 steel roller bearings were compared with equivalent bearings treated with Dicronite dry lubrication under sudden lubrication-loss conditions.
Standard
M-50 steel roller bearings
Untreated bearings.
Dicronite®
Equivalent treated bearings
Treated with Dicronite dry lubrication.
Test parameters
- Bearing material
- M-50 steel
- Bearing type
- Roller bearing
- Rotational speed
- 10,000 rpm at the inner race
- Initial lubricant
- MIL-PRF-7808 lubricant
- Test condition
- Sudden loss of lubrication
- Performance measures
- Operating time and outer-race temperature
The results
38 minutes, versus 3–6 minutes
- Standard bearingsFailed within 3–6 minutes3–6 minfailed
- Dicronite-treated bearingContinued operating through the full 38-minute test38 mintest ended
The Dicronite-treated bearing completed the test without a reported failure. Its ultimate time to failure was not established because testing ended at 38 minutes.
The outcome
Supporting emergency-landing requirements
According to the supplied test summary, the extended bearing operation met the military test conditions intended to allow time for an emergency landing.
These results demonstrate performance under the reported bearing-test conditions. They do not establish a universal operating time for every helicopter transmission following lubricant loss.
Contact Dicronite Southwest
Discuss your aerospace bearing application
Contact Dicronite Southwest to discuss dry lubrication for bearings and transmission components operating under demanding conditions.