Industries · Medical devices
Dry Lubrication for Medical Devices
Reduce Friction, Wear, and Galling in Precision Components
Dicronite® dry lubrication helps address friction and wear in medical-device components, surgical instruments, and diagnostic equipment. Its ultrathin film supports precision assemblies where smooth movement and tight mechanical tolerances are essential.
Applications include dental equipment, surgical tool pivots, guide mechanisms, and moving components within medical imaging systems.
- 0.030 Reported coefficient of friction As low as; depends on application conditions.
- 0.5µm Maximum film thickness For close-tolerance components.
- 7 Tests and documents listed Including ISO 10993-5 and an FDA Device Master File.
Why Dicronite®
Functional properties
-
Low friction
A reported coefficient of friction as low as 0.030 helps reduce resistance between moving surfaces. Performance depends on application conditions.
-
Precision film thickness
A maximum thickness of 0.5 microns supports close-tolerance components and helps address stick-slip and galling.
-
Wide temperature capability
A reported functional range of −188°C to +538°C supports demanding operating environments.
-
Radiation stability
Reported resistance to gamma radiation and X-rays supports evaluation for sterilization and imaging applications.
-
Medical application testing
Biocompatibility and sterilization-related test documentation supports assessment for the intended device application.
Testing and documentation
Testing and technical documentation
Dicronite’s reported testing and supporting documentation include:
| Test or documentation | Evaluation area |
|---|---|
| ISO 10993-5 | In vitro cytotoxicity |
| ISO 13402 | Surgical and dental hand-instrument resistance to autoclaving, corrosion, and thermal exposure |
| ASTM F1089 | Corrosion testing of surgical instruments |
| Gamma radiation testing | Stability under gamma sterilization exposure |
| ASTM F945 | Titanium-alloy stress-corrosion evaluation using aircraft-engine cleaning materials |
| ASTM E595 | Outgassing in a vacuum environment |
| FDA Device Master File | Supporting information for device regulatory submissions |
Contact Dicronite Southwest to discuss applicable test reports, sterilization conditions, and additional testing requirements.
Biocompatibility and sterilization suitability must be evaluated for the finished device and its intended use.
Applications
Example medical applications
-
Dental Equipment
Lubrication of dental air-drill gears and bearings to reduce friction and wear, with the aim of extending component life and reducing maintenance.
-
Surgical Instruments
Hinge and pivot lubrication to support smooth actuation, precise movement, and reduced wear.
-
Orthopedic Fixation Hardware
Anti-galling treatment for titanium and stainless steel mating components.
-
Medical Imaging Equipment
Lubrication of bearings, magnetic motion components, and linear guides operating in vacuum environments.
-
Guidewires, Cannulae, and Endosurgical Tools
Treatment of sliding interfaces to help reduce insertion force and minimize galling.
-
Ophthalmic Biopsy Devices
Lubrication between concentric sampling tubes to help prevent galling and reduce actuation force.
Contact Dicronite Southwest
Discuss your medical-device application
Contact Dicronite Southwest to review your component materials, mechanical tolerances, operating conditions, and testing requirements.