Case study · Gearboxes

Gearbox Temperature Reduction

16% Lower Operating Temperatures with Dicronite® Dry Lubrication

A major paper manufacturer tested Dicronite dry lubrication to address excessive gearbox temperatures during continuous operation. The critical gearbox achieved a 16% reduction in operating temperatures, exceeding the engineering requirement for a reduction greater than 10%.

Gearbox, cut away Dicronite® film Temperature control target >10% −16%
Dicronite® filmOperating temperature vs. control
  • 16% Lower operating temperature In the critical gearbox.
  • >10% Engineering requirement Exceeded, without external cooling equipment.
  • 27days Continuous operation Control gearboxes versus Dicronite-treated gearboxes.

The challenge

Critical temperatures inside the gearbox

The manufacturer was experiencing unacceptable gearbox wear and unscheduled maintenance. The issue was traced to critical temperatures inside the gearbox during continuous operation.

The engineering team wanted to lower gearbox temperatures by more than 10% without installing external cooling equipment.

Engineering requirement

>10%

Lower gearbox operating temperature.

Without installing external cooling equipment.

The testing

Control gearboxes versus treated gearboxes

Testing compared untreated control gearboxes with corresponding gearboxes treated with Dicronite dry lubrication.

Control

Untreated gearboxes

Operated without Dicronite dry lubrication.

Dicronite®

Treated gearboxes

Corresponding gearboxes treated with Dicronite dry lubrication.

Test parameters

Gearbox manufacturers
Radicon and Cleveland
Comparison
Control gearboxes versus Dicronite-treated gearboxes
Reported operating speed
479 feet per minute; maximum of 600 feet per minute
Test duration
27 days of continuous operation

The results

16% lower, beating the 10% target

Operating temperatures in the critical gearbox decreased by 16%, exceeding the engineering requirement.

  • Engineering requirementMore than 10% lower>10%required
  • Critical gearbox, Dicronite-treatedReduction in operating temperature16%achieved

Each bar is the temperature reduction, on a scale of 0 to 100%.

Following these results, Dicronite dry lubrication was incorporated into the plant’s engineering requirements.

Discuss your gearbox application

Looking to address gearbox temperature or component wear?

Contact Dicronite Southwest to discuss your operating conditions and dry lubrication requirements.

Dicronite® Southwest

Request a Dicronite® WS₂ Coating Quote

Send us your project details so we can evaluate your requirements and prepare a quote.

Sending drawings securely

Dicronite® Southwest is CMMC compliant. Please do not attach drawings to this form. Send drawings, including ITAR and CUI technical data, by email to rfq@secure.dicronitesouthwest.com. Email to this secure address is routed into our PreVeil encrypted environment.

Submit this form first so our team can add your email address, or your company's email domain, to the approved list for the secure inbox. Email from addresses that are not on the list cannot be received.

If your company already uses PreVeil, you can also send drawings to us directly through PreVeil.

Email Drawings Securely

Loading the quote form…

Thank you. Your quote request has been received.

Our team will review your project details and follow up by email.