Technical Article · Surface Engineering

Dicronite® on Anodized Aluminum and Titanium: Engineering Considerations

How anodize type, sealing, PTFE impregnation and surface roughness decide whether a 0.5 µm Dicronite® WS2 dry film stays anchored and keeps lubricating.

Dicronite Southwest 7 min read Based on LSI Technical Bulletin 0426-2

Interactive graphic

Inside an Anodized Surface Coated with Dicronite®

Switch the surface condition, or select a numbered point or a card to see the details.

Anodized Aluminum · Cross Section, Not to Scale

Surface condition

Tap a number or swipe to see the next point.

Introduction

Anodizing and Dicronite® Have to Be Planned Together

Anodizing is widely used on aluminum and titanium components to improve corrosion resistance and surface stability and, on aluminum, wear resistance through a harder surface.

In many advanced applications, the anodized part is then treated with a dry film lubricant such as tungsten disulfide (WS2) applied by the Dicronite® DL-5® process, to reduce friction and improve performance under boundary lubrication conditions.

Combining the two successfully is not trivial. It depends on surface morphology, post-treatment processes and the loads at the contact. This article looks at the anodizing processes, the effect of sealing and PTFE impregnation, and the role of surface roughness and contact mechanics in how a thin, low-friction coating such as Dicronite® performs.

The substrate

What an Anodized Layer Is

Anodizing is an electrochemical conversion process: the surface of the part is oxidized to form a coherent oxide layer. Aluminum forms aluminum oxide (Al2O3); titanium forms titanium dioxide (TiO2).

Unlike a deposited coating, the anodized layer is part of the substrate. It grows both inward into the material and outward from the original surface. On aluminum, the result is a highly ordered, columnar, porous structure.

That porous structure is central to how any later coating performs, because it governs both mechanical interlocking and the surface's ability to hold a lubricating film.

Aluminum

Aluminum Anodizing Processes

Each type of aluminum anodizing produces a different surface.

  • Sulfuric Acid, Type II

    A moderately hard, porous oxide for general corrosion protection and decorative use.

    5–25 µm
  • Hard Anodize, Type III

    Run at much lower temperatures. Harder and more wear-resistant, but process dependent, and it can show brittleness and micro-cracking, especially above about 50 µm.

    25–75+ µm · 400–600 HV
  • Chromic Acid

    A thinner layer, commonly specified in aerospace where fatigue performance and corrosion resistance are critical.

    2–5 µm
  • Phosphoric Acid

    Produces a highly porous structure and is used mainly where adhesive bonding is required.

    Highly porous

Anodizing does not smooth the surface. It replicates, and can amplify, the existing surface topography, while adding nanoscale pores.

Titanium

Titanium Anodizing Is Different

Titanium anodizing differs from aluminum anodizing in both purpose and outcome. It forms a thin titanium dioxide layer, typically much thinner than anodized aluminum, and is used mainly for corrosion resistance, color coding and biocompatibility rather than wear resistance or hardness.

Titanium components therefore generally rely on a secondary coating such as Dicronite® for meaningful tribological performance. The thin, dense oxide on titanium also presents different adhesion characteristics from the porous structure of anodized aluminum.

  • Corrosion resistance
  • Color coding
  • Biocompatibility
  • Relies on a secondary coating for wear

Post-treatments

Sealing and PTFE Impregnation

After anodizing, aluminum parts are often sealed to improve corrosion resistance, typically with a hydrothermal treatment or a nickel acetate solution that hydrates and closes the pores. Sealing works for corrosion protection, but it reduces the porosity that would otherwise let a later coating interlock mechanically. Lightly sealed surfaces may be partially reactivated through surface conditioning.

Some anodized surfaces are also impregnated with polytetrafluoroethylene (PTFE), which puts a low-friction polymer into the pores. For a coating applied afterward, such as Dicronite®, this creates significant problems:

  • Very low surface energy
  • Chemically inert interface
  • Poor coating adhesion
  • Poor coating retention
  • Higher risk of delamination under load

PTFE may give short-term friction reduction, but it fundamentally compromises the long-term performance of a mechanically bonded dry film lubricant.

Regulation

PFAS Restrictions

PTFE belongs to the broader class of per- and polyfluoroalkyl substances (PFAS), known as forever chemicals. PFAS are under increasing regulatory scrutiny and restriction as environmental legislation evolves, including the EU and UK REACH frameworks. These regulations are driving a shift away from fluoropolymer materials across many industries, particularly aerospace and high-performance engineering.

Dicronite® DL-5® offers a viable, environmentally compliant alternative. It provides excellent lubrication under boundary conditions without relying on PFAS chemistry, which makes it increasingly attractive as a replacement technology.

Surface roughness

How Roughness Carries Through Anodizing

The roughness of the aluminum before anodizing depends on how it was manufactured, from relatively smooth machined finishes to much rougher surfaces. Anodizing preserves and often accentuates that topography: the oxide follows the contour of the substrate, and the pores increase the effective surface area. Hard anodizing can add roughness through internal stresses and micro-cracking in the oxide.

0.5 µmA Dicronite® film this thin does not level or mask the surface profile. It conforms to the existing peaks and valleys, so the starting surface condition is a critical factor in performance.

Contact mechanics

Tribology at the Micro-Contacts

Two surfaces do not touch across their whole apparent area. They touch at discrete high points, called asperities, and those micro-contacts carry highly concentrated stresses, often in the gigapascal range depending on load and material properties.

Anodized surfaces, especially hard anodize, put high hardness at those peaks. That reduces plastic deformation but increases local stress concentration. A thin, soft coating then performs only as well as it stays anchored to the surface and keeps a continuous lubricating film.

Dicronite® DL-5® is a modified tungsten disulfide with a lamellar crystal structure: the layers are strongly bonded within each plane but held to each other only by weak van der Waals forces. Under load, shear happens between those weakly bonded planes.

µ 0.03–0.07Typical coefficient of friction under boundary lubrication conditions, from solid-state shear between the WS2 planes.

Well suited to

  • High loads
  • Low speeds
  • Vacuum environments
  • Places where wet lubricants cannot be used

Where roughness is controlled and the pores stay open, the coating can sit in the valleys and pores, acting as a reservoir that keeps a stable boundary lubrication regime. On smooth or sealed surfaces, and especially PTFE-impregnated ones, the coating is more easily pushed off the peaks, which can lead to premature loss of lubrication.

Results

How Dicronite® Performs on Anodized Surfaces

The effectiveness of the coating depends heavily on the condition of the anodized substrate.

Open, moderately rough anodize

An excellent foundation for adhesion and retention, so the lubricant keeps working under boundary conditions.

Sealed or PTFE-impregnated anodize

Little mechanical interlocking and lower surface energy, leading to shorter coating life and inconsistent friction behavior.

Specify the anodizing process and any later treatments with the intended coating and operating environment in mind, not as an afterthought.

Specifying the part

Engineering Recommendations

For the best Dicronite® performance on anodized aluminum, control the anodizing process to balance hardness, porosity and surface roughness.

  • Use unsealed or minimally sealed anodize, so enough porosity remains for adhesion
  • Avoid PTFE impregnation where Dicronite® will be applied, for adhesion and because of PFAS restrictions
  • Keep surface roughness in a moderate range of 0.3 to 0.6 µm, for interlocking without excessive stress concentrations
  • Specify anodizing and any post-treatment with the coating and application environment in mind

Conclusion

Engineer the Surface for the Coating

Combining anodizing with Dicronite® dry film lubrication takes a whole-surface engineering approach. Anodizing gives a robust, corrosion-resistant surface, but how well it works under Dicronite® depends on its post-treatment, its surface structure and the loads at the contact.

Sealing and PTFE impregnation, useful on their own, are fundamentally incompatible with a mechanically bonded lubricious coating, and growing pressure on PFAS materials is speeding the need for alternatives. Tungsten disulfide coatings such as Dicronite® DL-5® offer a technically and environmentally viable solution when the substrate is engineered to support adhesion and film stability. Optimizing roughness, porosity and the coating interface is what delivers reliable, repeatable performance in demanding applications.

Coating Anodized Aluminum or Titanium Parts?

Send us your part, anodize specification and any sealing or post-treatment details, and we will help you plan the surface for the best Dicronite® performance.

Dicronite® Southwest

Request a Dicronite® WS₂ Coating Quote

Send us your project details so we can evaluate your requirements and prepare a quote.

Sending drawings securely

Dicronite® Southwest is CMMC compliant. Please do not attach drawings to this form. Send drawings, including ITAR and CUI technical data, by email to rfq@secure.dicronitesouthwest.com. Email to this secure address is routed into our PreVeil encrypted environment.

Submit this form first so our team can add your email address, or your company's email domain, to the approved list for the secure inbox. Email from addresses that are not on the list cannot be received.

If your company already uses PreVeil, you can also send drawings to us directly through PreVeil.

Email Drawings Securely

Loading the quote form…

Thank you. Your quote request has been received.

Our team will review your project details and follow up by email.